Air-Mass Sensor <<1 <<2 <<3 <<4
 
DATA ARRAY
NOMINAL INPUT VOLTAGE
14V
RANGE OF INPUT VOLTAGE
8…17V
OUT VOLTAGE
0…5V
INCOMING CURRENT
<0.1A
AVAILABLE VIBRATION ACCELERATION
<150ms
-2
TIMECONSTANT
≤15MS
≤30MS
TEMPERATURE INTERVAL
-40…120℃
3
PART NO.
0280217123
0280218019
0280217531
0280218008
Upon reauest
MEASURING RANGE
8…370kg/h
10…480kg/h
12…640kg/h
12…850kg/h
15…1000kg/h
PRECISION
≤3%
≤3%
≤3%
≤3%
≤3%
ADAPTED LENGTH
22mm
22mm
22mm
16mm
22mm
ASSEMBLED LENGTH
20mm
20mm
20mm
16mm
20mm
INTERFACE DIAMETER
96mm
96mm
130mm
100mm
130mm7
VENT DIAMETER
60mm
70mm
80mm
88/84mm
6
92mm
PSID
50mm
62mm
71mm
78mm
82mm
TEMPERATURE PICKUP
<20hpa
<15hpa
<15hpa
<15hpa
<15hpa
MODEL
yes
yes
yes
yes
yes
ENCLOSURE CONNECTION
1
2
3
4
5
ENCLOSURE CONNECTION
PLUG BODY
CONTACT TAG
SINGLE WASHER
ELECTRICAL CONDUCTOR SIZE
1 928 403 146
1 928 280 103
1 928 280 106
0.5…1mm
2
1 928 280 105
1 928 280 107
1.5…2.5mm
2
APPLICATION:
This is to use to measure air discharge in the gas engine. So you can make an adjustment on the amount of the fuel to eject according to the current motive, air pressure and air temperature.
The meaning of the code
Qm Air Quality Turnover Rate
△Qm: Absolutely Exact Value
△Qm/Qm: Relatively Exact Value
t△ The Time When The Measure Error≤5%
t63: The Time When The Change In Measured Value Up To 63%
UA(t)= U0+(UEnd+U0).(1-e-t/63)

APPLICATION:
It is necessary to maintain a certain air-fuel delivery ratio for the rule of auto-let limitate.
That demanded the sensor record the mass flux of actual air and output a corresponding
Message to open-loop and closed-loop control circuit.

DESIGN:
The tiny machine’s sensor is fixed in the inset sensor’s channel of carrent. The inset is
Fit to combination with air filter or make use of a measure air intake to combination with
a channel which air enters. In accordance with different air flux, we choose different air
intake. The tiny machine’s measure system make use of a mixture circuit. When the air
flow reflow, it can check out the reflow by evaluating the diagraph data.

THE WORK PRINCIPLE:
The heated sensor break up calories the air of the inhalation. the air discharge is more high
when the calories lost more .the final difference in temperature can be the calculation of air
quality which flows through the sensor.
A mixture circuit can evaluate this diagraph date, then can be accurately measured the
Amount of the air discharge and its flowing direction.
The sensor can’t record the whole quality of the flowing-air but only parts can be tested to,
So the tested quality be used to calculate this current of air quality.